很多电工师傅排管布线很在行,一到桥架环节就图省事:宽度按电缆根数估、板厚听老板报价、防腐全靠“看起来亮”。结果送电半年,槽盒中段塌腰、雨季切口冒黄锈、消防验收卡在普通镀锌代替防火桥架。
Many electricians are skilled in piping and wiring, and when it comes to cable trays, they try to save time by estimating the width based on the number of cables, listening to the boss's quotation for board thickness, and relying solely on "looking shiny" for corrosion prevention. After half a year of power transmission, the middle section of the trough box collapsed, yellow rust appeared on the cut during the rainy season, and the fire inspection was stuck in ordinary galvanized instead of fireproof bridge.

选型先按场景定结构:
Choose the structure based on the scenario first:
动力主缆、厂房大截面电缆→梯级式,通风好、自重轻、好放线。
Main power cable, large section cable in the factory building → cascade type, well ventilated, light weight, easy to lay out.
强弱电混布、要散热又要防灰→托盘式(带孔底板)。
Mixing strong and weak electricity, requiring heat dissipation and dust prevention → Tray type (with perforated bottom plate).
弱电、消防报警、防电磁干扰→槽式带盖板,全封闭才安心。
Weak current, fire alarm, anti electromagnetic interference → trough type with cover plate, fully enclosed for peace of mind.
地下室、管廊、户外连廊→热浸镀锌≥65μm,潮湿户外直接拉到≥85μm,别用电镀锌凑数。
Basement, pipe gallery, outdoor corridor → hot-dip galvanizing ≥ 65 μ m, directly pull to ≥ 85 μ m in damp outdoor areas, do not use electric galvanizing to make up the difference.
三个非常容易省错钱的点:
The three easiest ways to save money:
板厚和跨距绑定:300mm宽、1.5m跨距用1.2mm还行;跨距拉到2.5m或宽度超600mm,侧板至少1.5–2.0mm,不然挠度超1/200必下垂。
Plate thickness and span binding: 1.2mm is acceptable for a width of 300mm and a span of 1.5m; When the span is extended to 2.5m or the width exceeds 600mm, the side panel should be at least 1.5-2.0mm, otherwise the deflection exceeding 1/200 will sag.
填充率别塞满:动力电缆占内腔≤40%,控制线≤50%,留10%–20%扩容余量,否则夏天电缆发热没人兜底。
Fill rate should not be too high: power cables occupy ≤ 40% of the inner cavity, control cables ≤ 50%, leaving a 10-20% expansion margin, otherwise there will be no one to cover the cable heating in summer.
小件别买杂牌:连接片、托臂、接地跨接线(≥4mm²软铜线)要和主桥架同材质同防腐,很多桥架不是主体烂,是螺丝先锈断。
Don't buy miscellaneous items for small items: connecting pieces, support arms, and grounding jumper wires (≥ 4mm ² soft copper wire) should be made of the same material and anti-corrosion as the main bridge frame. Many bridge frames are not damaged by the main body, but by the screws rusting first.
大跨距管廊、车站站台这种项目,提前让厂家出荷载曲线和伸缩节方案,比开工后加吊架省钱十倍。
Projects such as large-span pipe galleries and station platforms require manufacturers to provide load curves and expansion joint schemes in advance, which saves ten times more money than adding hangers after construction begins.
本文由济南桥架友情奉献.更多有关的知识请点击:http://www.sddlqj.cn我们将会对您提出的疑问进行详细的解答,欢迎你登录网站留言.