欢迎您光临济南苏鑫电缆桥架有限公司网站!
联系济南苏鑫电缆桥架有限公司 / Contact us

济南苏鑫电缆桥架有限公司

客户咨询热线

0531-85767688

售后热线:15668327566

联系基地:山东省 德州市协同发展产业园D06幢

400济南电缆桥架能放几根240电缆

文章来源:https://www.sddlqj.cn/   作者:电缆桥架厂家发布时间:2025-12-20 浏览次数:1

返回:公司新闻

  根据搜索结果,400桥架(宽度为400mm)能容纳的240平方毫米电缆数量取决于电缆的外径、桥架高度以及电缆敷设的排列方式。以下是综合分析:

  According to the search results, the number of 240 square millimeter cables that can be accommodated by a 400 meter bridge (with a width of 400mm) depends on the outer diameter of the cables, the height of the bridge, and the arrangement of cable laying. The following is a comprehensive analysis:
梯级式桥架-001

  电缆规范

  Cable plot ratio specification

  电缆桥架的电缆填充率通常不超过40%-50%(动力电缆)或50%-70%(控制电缆),需预留10%-25%的发展余量。若按40%的填充率计算,400×200桥架的有效截面积为32,000平方毫米(400×200×40%)。

  The cable filling rate of cable trays usually does not exceed 40% -50% (power cables) or 50% -70% (control cables), and a development margin of 10% -25% needs to be reserved. If calculated at a filling rate of 40%, the effective cross-sectional area of the 400 × 200 bridge is 32000 square millimeters (400 × 200 × 40%).

  电缆外径与数量估算

  Estimation of Cable Outer Diameter and Quantity

  3×240+2×120规格的电缆外径约为35.78mm(以VV型为例)。

  The outer diameter of a cable with specifications of 3 × 240+2 × 120 is approximately 35.78mm (taking VV type as an example).

  单根电缆占用面积约为π×(35.78/2)?≈1005平方毫米。

  What is the area occupied by a single cable approximately π× (35.78/2)? ≈ 1005 square millimeters.

  理论数量为32,000/1005≈31根,但实际需考虑间距、弯曲半径及散热要求:

  The theoretical maximum quantity is 32000/1005 ≈ 31, but in practice, spacing, bending radius, and heat dissipation requirements need to be considered:

  若电缆间预留5-10mm间隙,每层可放置约(400-2×25-10)/(35.78+10)≈7根(单层)。

  If a 5-10mm gap is reserved between cables, approximately (400-2 × 25-10)/(35.78+10) ≈ 7 cables can be placed on each layer (single layer).

  若桥架高度为200mm,可叠放2-3层,总数量约14-21根。

  If the height of the bridge is 200mm, it can be stacked 2-3 layers, with a total quantity of about 14-21 pieces.

  实际工程限制

  Actual engineering limitations

  电缆重量和固定方式(如电缆卡子)需确保桥架承重。

  The weight and fixing method of the cable (such as cable clamps) must ensure the safe load-bearing capacity of the cable tray.

  高压电缆(如10kV)需额外考虑距离,避免越级跳闸风险。

  High voltage cables (such as 10kV) require additional consideration of safety distance to avoid the risk of tripping beyond the designated level.

  综上,400×200桥架在单层敷设时可放约7根240电缆,多层敷设时多约20根,具体需根据电缆类型、桥架材质及工程要求调整。

  In summary, the 400 × 200 cable tray can accommodate approximately 7 240 cables when laid in a single layer, and up to 20 cables when laid in multiple layers. Specific adjustments need to be made based on cable type, tray material, and engineering requirements.

  本文由 济南电缆桥架   友情奉献.更多有关的知识请点击  http://www.sddlqj.cn/   真诚的态度.为您提供为的服务.更多有关的知识我们将会陆续向大家奉献.敬请期待.

  This article is a friendly contribution from Jinan Cable Bridge For more related knowledge, please click http://www.sddlqj.cn/ Sincere attitude To provide you with comprehensive services We will gradually contribute more relevant knowledge to everyone Coming soon.

工程案例 / Case Show
  • 济南火车站 济南火车站
  • 曲阜孔子文化会展中心 曲阜孔子文化会展中心
  • 山东工艺美院 山东工艺美院
  • 公安厅服务展示 公安厅服务展示